Operation Manual
FP+ Series Operation Manual 28
APPENDIX 6
Item no. CDTD_FP10000Q_V5
LAB.GRUPPEN AB ▸ SWEDEN
INTERNATIONAL CONTACT ▸ INFO@LABGRUPPEN.COM | US & CANADA CONTACT ▸ INFO@TCG-AMERICAS.COM
WWW.LABGRUPPEN.COM
VHF
TEM
NOMAD
LINK
BRIDGE C+D
SIG -20 -15 -10 -4
VPL CPL
SIG -20 -15 -10 -4
VPL CPL
BRIDGE A+B
MUTE
MUTE
SIG -20 -15 -10 -4
VPL CPL
SIG -20 -15 -10 -4
VPL CPL
HI-IMP
HI-IMP
HI-IMP
HI-IMP
CLIP
CLIP
CLIP
CLIP
VHF
TEM
VHF
TEM
VHF
TEM
PWR
PAL
FP10000Q
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
channel
A
B
channel
C
channel
D
channel
FP SERIES
R
POW
POW
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
Current Draw and Thermal Dissipation
FP+ Series: Dedicated Touring Amplifi ers
FP 10000Q
FP 10000Q
Level Load Rated Power
Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
0 0 0 0 0
Power on, Idling 139 0 139 475 120
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 660 x 4
10.7 5.6 732 330 402 1371 345
32 Ω / Bridged 1320 x 2
8 Ω / Ch. 1300 x 4
16.9 8.8 1224 650 574 1958 493
16 Ω / Bridged 2600 x 2
4 Ω / Ch. 2100 x 4
25.9 13.5 1914 1050 864 2949 743
8 Ω / Bridged 4200 x 2
2 Ω / Ch. *4) 2500 x 4
32.2 16.8 2414 1250 116 4 3973 1001
4 Ω / Bridged *4) 5000 x 2
Pink noise
(max power)
*3)
16 Ω / Ch. 660 x 4
13.6 7.1 114 3 880 263 897 226
32 Ω / Bridged 1320 x 2
8 Ω / Ch. 1300 x 4
22.4 11.7 2096 1733 363 1238 312
16 Ω / Bridged 2600 x 2
4 Ω / Ch. 2100 x 4
30.0 16.0 2377 / 2455 1466 / 1542 910 / 914 3107 / 3118 783 716
8 Ω / Bridged 4200 x 2
2 Ω / Ch. 2500 x 4
30.0 16.0 2237 / 2291 1099 / 1145 1139 / 114 6 3886 / 3911 979 / 985
4 Ω / Bridged 5000 x 2
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 6.4f: FP 10000Q Current Draw and Thermal Dissipation specications