FP 4000
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
0.1 0.2 0 0 1 0
Power on, Idling 0.8 87 0 87 298 75
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 400 x 2
3.9 2.0 262 100 162 552 139
32 Ω / Bridged 800 x 1
8 Ω / Ch. 800 x 2
6.1 3.2 424 200 224 765 193
16 Ω / Bridged 1600 x 1
4 Ω / Ch. 1600 x 2
10.7 5.6 782 400 382 1305 329
8 Ω / Bridged 3200 x 1
2 Ω / Ch. 2000 x 2
14.2 7.4 1035 575 460 1569 395
4 Ω / Bridged 4000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch. 400 x 2
7.0 3.7 499 267 232 793 200
32 Ω / Bridged 800 x 1
8 Ω / Ch. 800 x 2
12.1 6.3 893 533 359 1227 309
16 Ω / Bridged 1600 x 1
4 Ω / Ch. 1600 x 2
21.7 11. 3 1681 1067 615 2098 529
8 Ω / Bridged 3200 x 1
2 Ω / Ch. 2000 x 2
28.6 14.9 2226 1533 692 2363 595
4 Ω / Bridged 4000 x 1
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 20 A, Nema 5-20P
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
Table 6.4e: FP 4000 Current Draw and Thermal Dissipation specications