Operation Manual
FP+ Series Operation Manual 26
APPENDIX 6
FP 7000
Level Load Rated power Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
0 0 0 0 0
Power on, Idling 92 0 92 316 80
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 730 x 2
6.5 3.4 411 183 229 781 197
32 Ω / Bridged 1460 x 1
8 Ω / Ch. 1450 x 2
10.4 5.4 692 363 329 1123 283
16 Ω / Bridged 2900 x 1
4 Ω / Ch. 2800 x 2
16.8 8.7 1176 700 476 1625 409
8 Ω / Bridged 5600 x 1
2 Ω / Ch. 3500 x 2
21.1 11.0 1518 875 643 2195 553
4 Ω / Bridged 7000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch. 730 x 2
18.9 9.8 800 487 313 1070 270
32 Ω / Bridged 1460 x 1
8 Ω / Ch. 1450 x 2
30.0 16.0 1425 / 1436 914 / 924 511 / 512 174 4 / 1749 439 / 441
16 Ω / Bridged 2900 x 1
4 Ω / Ch. 2800 x 2
30.0 16.0 2134 / 2183 1382 / 1419 753 / 763 2569 / 2605 647 / 656
8 Ω / Bridged 5600 x 1
2 Ω / Ch. 3500 x 2
30.0 16.0 2316 / 2380 1526 / 1586 790 / 794 2696 / 2710 679 / 683
4 Ω / Bridged 7000 x 1
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
Table 6.4d: FP 7000 Current Draw and Thermal Dissipation specications