Operation Manual
25 FP+ Series Operation Manual
6 APPENDIX
FP 9000
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
1 0 1 3 1
Power on, Idling 122 0 122 416 105
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 800 x 2
6.7 3.5 477 200 277 944 238
32 Ω / Bridged 1600 x 1
8 Ω / Ch. 1600 x 2
11. 0 5.7 799 400 399 1362 343
16 Ω / Bridged 3200 x 1
4 Ω / Ch. 3000 x 2
18.5 9.7 1398 750 648 2212 557
8 Ω / Bridged 6000 x 1
2 Ω / Ch. 4500 x 2
26.3 13.7 2053 1125 928 3166 798
4 Ω / Bridged 9000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch. 800 x 2
12.2 6.4 930 533 396 1352 341
32 Ω / Bridged 1600 x 1
8 Ω / Ch. 1600 x 2
22.0 11. 5 1707 1067 640 2185 550
16 Ω / Bridged 3200 x 1
4 Ω / Ch. 3000 x 2
30.0 16.0 2278 / 2430 1419 / 1514 859 / 916 2931 / 3126 738 / 788
8 Ω / Bridged 6000 x 1
2 Ω / Ch. 4500 x 2
30.0 16.0 2258 / 2409 1219 / 1300 1039 / 1109 3548 / 3784 894 / 953
4 Ω / Bridged 9000 x 1
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
Table 6.4c: FP 9000 Current Draw and Thermal Dissipation specications