FP 13000
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via Nomadlink
®
0 0 0 0 0
Power on, Idling 129 0 129 440 111
Amp (I) Watt
Pink noise
(1/8th rated
power)
16 Ω / Ch. 1200 x 2
10.2 5.3 678 300 378 1289 325
32 Ω / Bridged 2400 x 1
8 Ω / Ch. 2350 x 2
15.6 8 .1 1083 588 495 1690 426
16 Ω / Bridged 4700 x 1
4 Ω / Ch. 4400 x 2
25.4 13.2 1856 110 0 756 2578 650
8 Ω / Bridged 8800 x 1
2 Ω / Ch. *4) 6500 x 2
36.2 18.9 2536 1625 911 3109 783
4 Ω / Bridged *4) 13000 x 1
Pink noise
(max power)
*3)
16 Ω / Ch. 1200 x 2
15.3 8.0 1037 800 237 807 203
32 Ω / Bridged 2400 x 1
8 Ω / Ch. 2350 x 2
26.0 13.6 1840 1567 273 933 235
16 Ω / Bridged 4700 x 1
4 Ω / Ch. 4400 x 2
30.0 16.0 2199 / 2249 1435 /1487 764 / 763 2609 / 2603 657 / 656
8 Ω / Bridged 8800 x 1
2 Ω / Ch. 6500 x 2
30.0 16.0 2041 / 2093 1227 / 1267 814 / 826 2778 / 2818 700 / 710
4 Ω / Bridged 13000 x 1
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 30 A, Twist lock
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and speci ed here
is what is known as the “Active Power” of the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation . Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Italics used for conditions that, if sustained over long time periods, may trigger the mains breaker. Therefore these measurements should not be used when
calculating cooling requirements as they cannot be sustained by the mains breaker over time.
Table 6.4b: FP 13000 Current Draw and Thermal Dissipation specications