4 QUICK GUIDE OVERVIEW
4.2.1 Network and Conguration section
Four-channel model shown. Two-channel versions
have VPL and Bridge Mode switches for channels
A and B only. All models have different VPL values.
Functions are otherwise identical.
44dB
41dB
38dB
35dB
32dB
29dB
26dB
23dB
150V
121V
101V
83V
70V
56V
47V
38V
Figure 4.2.2a: Rear panel DIP-switch field
4.2.2 The DIP-switch features
The following features may be adjusted using the
DIP-switches on the rear panel of the amplier.
Gain - Globally set for all channels, from +23 dB to
+44 dB in 3 dB steps.
Option active - Not currently implemented.
Fan Masked - When on, engages the intelligent
fan feature; fan speed is lowered when no signal is
present.
Bridge A+B and C+D- Switches the channel pairs
into bridge mode operation An automatic -6 dB gain
compensation is applied.
VPL - The Voltage Peak Limiter provides optimum
peak voltage settings for each channel. Level selec-
tions vary by model within the FP+ Series.
Mode - Select VPL mode to either Hard or Soft
operation. For channels driving sub-woofers and
low-frequency drivers, it is recommended to use
the Hard setting for optimal operation. For mid- and
high- frequency drivers, always select Soft.
VPL in Standard Mode
FP 14000 FP 13000 FP 9000 FP 7000 FP 4000 FP 10000Q FP 6000Q
195 V 195 V 170 V 155 V 121 V 150 V 101 V
170 V 170 V 140 V 121 V 101 V 121 V 83 V
140 V 140 V 116 V 101 V 83 V 101 V 70 V
116 V 116 V 100 V 83 V 70 V 83 V 56 V
100 V 100 V 80 V 70 V 56 V 70 V 47 V
80 V 80 V 66 V 56 V 47 V 56 V 38 V
66 V 66 V 54 V 47 V 38 V 47 V n/a
54 V 54 V n/a 38 V n/a 38 V n/a
VPL in Bridge Mode
FP 14000 FP 13000 FP 9000 FP 7000 FP 4000 FP 10000Q FP 6000Q
195 V 390 V 340 V 310 V 242 V 300 V 202 V
170 V 340 V 280 V 242 V 202 V 242 V 166 V
140 V 280 V 232 V 202 V 166 V 202 V 140 V
116 V 232 V 200 V 166 V 140 V 166 V 112 V
100 V 200 V 160 V 140 V 112 V 140 V 94 V
80 V 160 V 132 V 112 V 94 V 112 V 76 V
66 V 132 V 108 V 94 V 76 V 94 V n/a
54 V 108 V n/a 76 V n/a 76 V n/a
Table 6.2.2b: VPL voltage selections in Standard Mode