Operation Manual

5 FP+ Series Operation Manual
4 QUICK GUIDE OVERVIEW
The amplier’s front panel presents the performance
and fault condition indicators, power and remote
switches, and a removable dust-lter cover. Level
potentiometers provide individual attenuation for the
amplier channels. Range is 0 dB to - innity. (The
12 o’clock position indicates -10 dB attenuation.) A
convenient label strip with writing surface is provided
adjacent to each level potentiometer.
To remove the dust-lter covers, loosen the thumb-
screws located underneath the front handles. This
allows removal of the dust-lters for cleaning. The
covers may be made “tamper resistant” by replacing
the thumbscrews with Philips head or safety Torx
screw. Thread size is M3.
The amplier never should be operated
without the dust-lters in place.
4.1.1 Power on/off and remote switch
The Power on/off switch is located on the right side.
A second switch, labeled “REMOTE,” is above the
Power switch. When the Remote switch is on (with
mains connected and power on/off switch on), the
yellow LED above it will illuminate indicating that
external power on/off commands from the NomadLink
network connection will switch the amplier on or
off. When Remote is activated the amplier will not
switch on until a “Power On” command is received
from the network. When the remote switch is off,
it is not possible to switch amplier power on or off
using NomadLink network control.
4.1.2 Front-panel LED’s
The front-panel LED area includes the following
indicators per channel:
VHF
TEM
NOMAD
LINK
BRIDGE C+D
SIG -20 -15 -10 -4
VPL CPL
SIG -20 -15 -10 -4
VPL CPL
BRIDGE A+B
MUTE
MUTE
SIG -20 -15 -10 -4
VPL CPL
SIG -20 -15 -10 -4
VPL CPL
HI-IMP
HI-IMP
HI-IMP
HI-IMP
CLIP
CLIP
CLIP
CLIP
VHF
TEM
VHF
TEM
VHF
TEM
PWR
PAL
FP10000Q
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
-10dB
-inf
0
channel
A
B
channel
C
channel
D
channel
FP SERIES
R
POW
POW
4.1 Front-Panel overview
Figure 4.1.2a: Front panel LED eld (per-channel)
VHF
- Very High Frequency protection active (output muted)
(Yellow constant)
TEM - Temperature warning (Yellow ashing)
TEM - Temperature mute (Yellow constant)
MUTE - Channel muted via NomadLink network or due
to a fault condition (Red)
CPL - Current Peak Limiter (CPL) active (Orange ashing)
CPL - (Orange constant with output muted): Low impe-
dance / short circuit detection fault
VPL - Voltage Peak Limiter (VPL) active
SIG - Signal levels - 40 dB (Sig) to –4 dB
Hi-Imp - High-impedance/open load detected (Orange)
Bridge - Bridge mode operation (Yellow)
.
When no VPL, CPL or PAL indicators are illumi-
nated, and the VPL DIP-switch is set to maxi-
mum at the specied nominal load, the ampli-
er channel is able to deliver maximum rated
output power
(PWR) Power on (Green)
(PAL) Power Average Limiter active
(Red)
NomadLink network active (Blue)
Figure 4.1.2b: Front panel global LED eld
When the network is connected,the blue
NomadLink LED will illuminate even when
mains power is not connected. NomadLink
receives phantom power from the network
as supplied by the NLB 60E.