Maximum Output Power
4 or 8  per channel 60 W 120 W 240 W
Number of Ouput Channels
Number 2
Minimun Load Impedance
4  mode 4 
8  mode 8 
70 V output mode 82  41  20 
100 V output mode 166 82  41 
Controls
Front N/A
Rear Gain control, input sensitivty select (4 dBu / -10 dBV), load cong (4  / 8  / 70 V / 100 V), switchable 80 Hz high-pass lter
Indicators
Power On (blue), standby (yellow)
Limit (red LED), per channel Input clip, output limit
Signal (green LED), per channel >1.23 mV (-56 dBu)
Fault (red LED) Overheat, DC fault, over current etc
System
Inputs 2 x 3-pin 5.08 mm Euroblock connector
Input impedance 10 k unbalanced, 20 k balanced
Input sensitivty Balanced: 1.23 V (+4 dBu) or 316 mV (-10 dBV)
Maximum input level 9.75 V (+22 dBu)
Outputs 1 x 4-pin 5.08 mm Euroblock connector
Output circuit type Class D
Remote connector 2 x RJ45 Ethernet connector
Distortion, ⁄ rated power <0.5%
Frequency response 20 Hz to 20 kHz, +0.5 / -1 dB
Crosstalk >65 dB
Signal-to-noise >100 dBA
High-pass lter 80 Hz HPF
Cooling Convection-cooled, fanless
Amplier protection Thermal protection, over current protection, DC protection, high frequency protection
Load protection Controlled start and shutdown behaviour, DC-fault protection
Main voltage 100-240 V~, 50/60 Hz with active power factor correction
Power consumption ⁄th rated power @ 4  50 W 70 W 120 W
Mains connector Standard IEC connector
Dimensions (H x W x D) 44 x 218 x 280 mm (1.7 x 8.6 x 11.0")
Weight 2.6 kg (5.7 lbs)
Finish Brushed black anodized aluminum chassis with black painted steel bottom
Approvals CE, WEEE, CCC, cTUVus, PSE, RCM, RoHS, FCC part 15 Class B, Energy Star 3.0
Performance
Specications
Circuit Protection
Power Supply, Voltage
Dimensions / Weight