The following tables contain information on measured current consumption as well as calculated heat dissipation during what we see as
the most extreme sustained normal operation (1/8 rated power).
E 12:2
Level Load Rated power
Mains
voltage
Line
current
Watt *1) Thermal Dissipation
VAC IAC *2) In Out Dissipated BTU/hr kCal/hr
Standby
230 0.032 0.70 0.0 0.7 2.4 0.6
120 0.019 0.31 0.0 0.3 1.1 0.3
Power on, Idling
230 0.18 3 20.7 0.0 20.7 70.5 17.8
120 0.315 21.9 0.0 21.9 74.7 18.8
Pink Pseudo
Noise (1/8)
70 V / Ch. 600 x 2
230 1.8 210 150 60 205 52
120 2.9 223 150 73 248 62
16 Ω / Ch. 310 x 2
230 1.1 128 83 45 154 39
120 1.8 136 83 54 183 46
8 Ω / Ch. 600 x 2
230 1.8 209 150 59 202 51
120 2.9 219 150 69 237 60
4 Ω / Ch. 600 x 2
230 1.9 222 150 72 245 62
120 2.9 226 150 76 259 65
2 Ω / Ch. 600 X 2
230
2.0 249 150 99 337 85
120
3.1 252 150 102 349 88
*1) The amplier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specied here
is what is known as the “Active Power” in the amplier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. as well as 120 V. The efciency is similar, but not identical for the two scenarios. The efciency for 100 V mains is