A & E Specifications
WWW.LABGRUPPEN.COM
Item no. AES-E10:4 - 15.03.16
Overview: Certification and Channel Modes
The power amplier shall be Energy Star 3.0 certied. It shall provide
four discrete channels of amplication, with each channel capable of
independently driving either low-impedance or high-impedance (70 V)
loads. The output circuit shall be an inherently bridged Class D
topology. Maximum total output with four channels driven shall be
1000 W.
Power Output and Performance
The power amplier shall offer two power output modes (Lo-Z and
70 V) selectable by a rear-panel switch. Power output per channel,
all channels driven, shall be as follows in Lo-Z mode: 250 W into
4 ohms, 250 W into 8 ohms and 125 W into 16 ohms. Power
output per channel, all channels driven, shall be as follows in 70 V
mode: 250 W into 16 ohms, and 250 W into a 70 V system. The
amplier shall incorporate a rail voltage sensing circuit to ensure low
distortion. Peak voltage output per channel shall be 100 V (70 V rms);
maximum output current per channel shall be 14 Arms. Power output
higher than stated prior shall be possible into any of the channels
with asymmetrical loading or with one or more channels without a
load. Gain shall be 35.2 dB in 70 V mode and 31.2 dB in Lo-Z mode.
The amplier shall exhibit the following performance parameters:
Frequency response shall be 2 Hz to 40 kHz (+0/-3 dB at 1 watt into
an 8 ohm load); channel separation shall be greater than 70 dB; and
signal-to-noise ratio shall be greater than 112 dBA. THD at 1 watt
(20 Hz - 7 kHz) shall be less than 0.1%; THD at 1 kHz shall be no more
than 0.05% at 1 dB below clipping.
Connectors, Controls, and Indicators
The following connectors and controls shall be provided on the REAR
PANEL of the amplier. The input connectors shall be electronically
balanced, 3-pin detachable screw terminals. The output connectors
shall be 2-pin detachable screw connectors. GPIO (General Purpose
Input/Output) functions shall be provided on two 2-pole detachable
screw terminal connectors. Four potentiometers shall provide level
adjustment from -innity to 0 dB. A power switch shall toggle
between On and Standby power states. The following LED indicators
shall be provided on the FRONT PANEL of the amplier: One bi-color
power indicator (amber standby, green on); one temperature indicator
(ashing amber warning and steady amber over-temperature/mute);
two LED indicators per channel, one for signal present and one for
limiter active.
Power Supply, Protection, and Cooling
The power supply shall be a universal type (AC line input between
100 and 240 VAC at 50 or 60 Hz). The power supply shall offer three
modes for power on/standby/off. Default mode shall be auto-power
down (APD): the amplier shall go into standby mode when no signal
is present at the inputs for 20 minutes; power on mode shall resume
with restoration of input signal. Standby power consumption shall be
less than 1 W. Alternative power modes shall be manually switched
on/standby or external power sequencing via GPIO connections.
The amplier shall be cooled by a temperature-controlled, variable-
speed fans with air ow from front to rear.
Physical
The amplier shall be 483 mm (19 in.) wide, 44 mm (1.75 in / 1 U)
high, and 381 mm (15 in.) deep. The weight shall be no more than
6.2 kg (13.7 lbs). The chassis shall be black painted steel with a grey
painted aluminum front-panel. The amplier shall be approved for use
as specied by CE. The amplier shall be the Lab.gruppen E 10:4.
E 10:4
Architects’ and Engineers’ Specification
E Series: Installation-Focused Amplifiers