Operation Manual
13. System configuration tutorial 
39
D SERIES Lake Operation Manual rev 3.0.4
13. System configuration tutorial 
38    
D SERIES Lake Operation Manual  rev 3.0.3
18.  Tap the Input Gain button in the block diagram and unmute the Module Input Mute. Tap EQ/Levels Exit to return to  
  IO Cong.
19.  The left side of the IO cong screen holds frame conguration and summary for Clock conguration, Input  
  conguration, Dante conguration, Breaker Emulation Limiter conguration and Analog Iso–Float & AES Termination  
  conguration. All these congurations should be correct by default for this example. 
20.  From I/O cong, tap Amplier Events & Control and navigate to the Status tab. Unmute the power channels and  
  slowly increase the volume on the appropriate feed from the mixing console. Audio should now be active at the  
  outputs and heard through the loudspeakers. Close the Amplier Events & Control dialog with the return button  
  and return to the main area by tapping the I/O Cong EXIT button. 
Levels Control – Drag sliders and tap mute buttons for module 
input and output channels.
Delay Control – Drag sliders to control input and output delay Crossover control – Select lters and drag on the bottom 
frequency bar to adjust crossover frequency. Crossover 
types may be changed by selecting the Crossover 
Functions button.
Parametric EQ control – Select lter on the top squares 
and adjust lter properties by dragging the controls. Sliders 
at the bottom control center frequency and Q (bandwidth). 
Gain is controlled in the main window area. Additional lters 
can be added by tapping the top lter objects and placing 
new lters on the main area. 
Amplier Events & Control, Status tab – Drag sliders to adjust power channel attenuation and tap mute 
buttons to control power channel mute. Metering and Status monitoring is available for each power channel.