Operation Manual
9. Front panel interface
15
D SERIES Lake Operation Manual rev 3.0.4
9. Front panel interface 
D SERIES Lake Operation Manual  rev 3.0.3
15    
9. Front panel interface 
9.1. Frame status and control 
NOTE: General status indication shown in Table 9.1. For detailed information on warning and fault 
indication, please refer to the Faults and Warnings table in Section 14.1.
1
  FRAME LED – Provides status indication for a number functions affecting the amplier frame
2
  TEMP LED – Provides status indication for internal temperatures sensed at multiple points, including power  
  supply, DSP and output channels
3
  PSU LED – Provides status indication on functionality of Power Supply Unit and mains supply, including under–  
  and over–voltage, power supply faults, and unstable mains supply
4
  POWER LED and TOUCH BUTTON – Provides power state indication and control. Press and hold button to  
  toggle the amplier between ON and STANDBY state. LED indication given in Table 9.1.
9.2. Channel status and control 
5
  LOAD LED – Provides load related status indication for monitoring functionality of LoadSmart and LoadPilot.  
  Warnings and faults indicate problems or anomalies detected in the connected loudspeakers and/or cabling
6
  AMP LED – Provides amplier related status indication, including faults and warnings related to temperature,  
  over–current, clipping and very high frequency
7
  SIGNAL LED – Provides signal related status indication, including no signal and input signal clipping
8
  MUTE LED and TOUCH BUTTON – Provides mute status indication and control. The LED is indicating  
  both Lake mutes and power channel mute. A single touch on the mute button toggles the power channel mute  
  between mute and unmuted states
9
  SELECT LED and TOUCH BUTTON – for selection and indication control between computer software and unit
1 2 5 6
43
7
9
8