Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Lake-enabled Amplifier Reference
269 
20.9.6  LoadSmart Results
LOAD RESULTS reports the ndings of the verication procedure. Results for each power output is 
displayed together with a summary in the ALL column.
20.9.6.1  Load Type Verication
The results shown in the Load type row of the table will be one of the following:
 ▸ CORRECT – The measured load characteristics closely match the values predicted from the load library 
data in combination with the total resistance calculation. 
 ▸ UNCERTAIN – The measured load characteristics exhibit a degree of variance from the predicted 
values. A warning becomes active on the channel.
 ▸ WRONG – The measured characteristics differ widely from the predicted values; it is assumed that 
the load has malfunctioned or is of the wrong type. A fault is issued and the channel remains muted. A 
successful re-verication, power cycle, or placing the device into standby mode, will clear the fault and 
the mute state.
 ▸ NO MODEL – Fingerprint data is missing from the Module le selected.
 ▸ ABORTED – A power output channel was in a protective state during the load verication process (e.g. 
temperature fault).
The ALL column summarizes the NUMBER OF 
CABINETS verication result from each power 
output channel in the order VERIFIED > WRONG. 
e.g. 2/1 = two channels match, one does not.
If LOAD TYPE VERIFICATION fails, the power 
output channel will be muted to prevent speaker 
damage. A subsequent CORRECT or UNCERTAIN 
verication (or power cycle) resolves the mute.
20.9.6.2  Cabinet Count Verication
The results in the NUMBER OF CABINETS row will be one of the following:
 ▸ VERIFIED – The measured load impedance indicates the number of cabinets connected to this power 
output matches that congured.
 ▸ WRONG – The measured load impedance indicates either that the number of cabinets connected to 
this power output channel is incorrect.
If the correct number of cabinets is entered but the 
results returned are wrong it is possible to force 
settings by selecting FORCE TO CONFIGURED.