Lake Controller Operation Manual Version 1.7.0
266  
Lake Controller Operation Manual Rev 1.7.0
Lake-enabled Amplifier Reference
20.9  LoadSmart Tab
The LoadSmart page is selected by tapping the LoadSmart tab in Module view. LoadSmart loudspeaker 
verication is initiated from this tab. LoadSmart generates a test signal which is applied to the power output 
stage. Measurements are taken at the power output stage, and the results computed for the speaker type, 
using data from the Fingerprint. It is specied in the LoadLibrary documentation which SpeakerPresets have 
Fingerprint data.
The LoadSmart tab is disabled if ngerprint data is 
not present, and also when the Lake-enabled 
amplier is in Standby mode.
Some LoadLibrary SpeakerPresets do not have 
associated Fingerprint data.
The LoadSmart tab allows editing of default cable data in the Fingerprint, including cable characteristics that 
are used in the calculation of the total cable resistance for each loudspeaker. The Lake Controller application 
combines this information with the known loudspeaker characteristics contained in the ngerprint to ac-
curately verify the load and to conrm correct loudspeaker system operation.
Figure 20-8: LoadSmart Tab  and Verication