Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
 - 2. Software Installation
 - 3. Network & Firewall Overview
 - 4. Lake Controller Tutorial
 - 5. Home Menu Reference
 - 6. EQ/Levels Menu Reference
 - 7. System Store Recall Menu Reference
 - 8. Modules Menu Reference
 - 10. Groups Menu Reference
 - 11. Solo/Mute Menu Reference
 - 12. Icon Control Menu Reference
 - 13. User Preferences Menu Reference
 - 14. Pages Menu Reference
 - 15. Network Menu Reference
 - 16. Communication and Synchronization
 - 17. Faults and Warnings
 - 18. Analyzer Plug-in
 - 19. Designer Mode Menu Reference
 - 20. Lake-enabled Amplifier Reference
 - 21. LM Series Reference and Operation
 - 22. MY8-LAKE Reference and Operation
 - 23. Keyboard Shortcuts
 - 24. External Control Interfaces
 - 25. Command Line Options
 - 26. Firmware Update
 - 27. Preset Manager
 - 28. IP Address Reference
 - 29. Corporate Information
 
Lake Controller Operation Manual Rev 1.5.9
Module File Types & Lake LoadLibrary™ 
175 
Figure 9-8: Linear Phase 2-Way + 1-Auxiliary Outputs
9.5.2  Linear Phase 3-Way
The Linear Phase 3-Way (LP3way) has a similar signal path to the Classic 3-Way (CL3way).
Figure 9-9: Linear Phase 3-Way
9.5.3  Linear Phase 2-/3-Way EQ/MaxPeak combinations
The LP2 and LP3way Modules use a signicant amount of processing power to create steep crossovers 
with at phase response. For this reason, the full amount of output-specic EQ lters can only be used if the 
MaxPeak is disabled on the Module, as the MaxPeak Limiter also requires a large amount of processing.
The MaxPeak Limiter process is disabled when the total MaxPeak level (including Group and factory set-
tings) is 25 dBu or greater. The following crossover EQ lters for the LP2 and LP3way are available:
 ▸ MaxPeak Activated:  10 EQ Filters + High-pass Filter
 ▸ MaxPeak Deactivated:  15 EQ Filters + High-pass Filter