Current Draw & Thermal Dissipation

D SERIES 80:4
Item no. CDTD-DSERIES804 - 02.09.2015
WWW.LABGRUPPEN.COM
D SERIES 80:4
Level Load
Rated power
per channel
Line Current
Power
Factor
Measured Power (W) Thermal Dissipation
(A) (%) In Out Dissipated BTU/hr kCal/hr
Mains Voltage 230 VAC, 16 A
Sleep (Tesira) 0.3 11 7 0 7 24 6
Standby (Lake) 0.3 17 12 0 12 39 10
Standby (Tesira) 0.3 23 17 0 17 59 15
Power on, Idling 1.0 89 193 0 193 660 166
Pink Pseudo
Noise
16 Ω / Ch. 750 4.2 99 948 375 573 1957 493
8 Ω / Ch. 1500 6.4 99 1443 74 9 694 2369 597
4 Ω / Ch. 2000 8 .1 99 1907 1000 906 3092 780
2.67 Ω / Ch. 2000 8.7 100 2052 1003 1049 3580 903
2 Ω / Ch. 2000 9.4 100 2200 1000 1201 4096 1033
LoadPilot
Sine 20 kHz
8 Ω / Ch. 1.0 89 204 0 204 695 175
Current Draw and Thermal Dissipation