Lake Controller Operation Manual Version 1.7.0
310  
Lake Controller Operation Manual Rev 1.7.0
Firmware Update
For PLM+ and D Series, the rmware update utility must be able to read the Dante component before the 
rmware update can start; ensure the network adapter selected for rmware update is on the same subnet 
as Dante (169.254.x.x) and ensure the Lake Update Utility has full access through the rewall. 
An hourglass will display with the text “Dante version...”; if this 
does not complete within 30 seconds, press the Refresh Dante 
button. If the issue continues, open the Dante Controller and 
press “Reload Device Information”, or restart the computer.
. 
6.  Tap SELECT OLD and then UPDATE. A warning message appears.
Figure 27-4: Firmware Update Warning Message
7.  Tap OK in response to the warning message. All selected devices are updated in parallel with the latest 
rmware. A green tick indicates the rmware is already at the latest version, a percentage indicates the 
update status for the devices currently being updated, and a red cross indicates the rmware is old and 
is awaiting update or the device requires a power-cycle to complete the upgrade.
Figure 27-5: Firmware Update Status
8.  Wait for all devices to be updated. For PLM+ and D Series (with rmware >2.58), the rmware update 
process will include a automatic power cycle.
For PLM, LM and MY8-LAKE, when the rmware is updated, a warning advises that the mains power must 
be cycled (using the standby button on the Front Panel is not sufcient). For the MY8-LAKE, please power-
cycle the host device.