Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
 - 2. Software Installation
 - 3. Network & Firewall Overview
 - 4. Lake Controller Tutorial
 - 5. Home Menu Reference
 - 6. EQ/Levels Menu Reference
 - 7. System Store Recall Menu Reference
 - 8. Modules Menu Reference
 - 10. Groups Menu Reference
 - 11. Solo/Mute Menu Reference
 - 12. Icon Control Menu Reference
 - 13. User Preferences Menu Reference
 - 14. Pages Menu Reference
 - 15. Network Menu Reference
 - 16. Communication and Synchronization
 - 17. Faults and Warnings
 - 18. Analyzer Plug-in
 - 19. Designer Mode Menu Reference
 - 20. Lake-enabled Amplifier Reference
 - 21. LM Series Reference and Operation
 - 22. MY8-LAKE Reference and Operation
 - 23. Keyboard Shortcuts
 - 24. External Control Interfaces
 - 25. Command Line Options
 - 26. Firmware Update
 - 27. Preset Manager
 - 28. IP Address Reference
 - 29. Corporate Information
 
184  
Lake Controller Operation Manual Rev 1.5.9
Groups Menu Reference
10.7.1  Gang Xover/Aux or Gang HPF/LPF
This button read GANG XOVER/AUX when a Group containing Contour Modules is selected, and GANG 
HPF/LPF when a Group containing Mesa EQ Modules is selected. These functions allow the crossovers, 
auxiliary output channels, and HPF/LPF settings of Modules on different Frames to be linked together.
 ▸ When GANG XOVER/AUX is active on a Group containing crossover Modules, the crossovers, HPF/LPF, 
and auxiliary channels of all Modules in the Group are synchronized. A change made in one Module will 
be reected in all Modules of that Group. 
 ▸ When Gang HPF/LPF is active on a Group containing Mesa EQ Modules, the HPF/LPF will be linked on 
all Modules in the Group.
To gang the crossover or HPF/LPF of all Modules in a Group, perform the following steps:
1.  Assign the Modules to a Group. All Modules must be of the same crossover type, such as Classic 
3-Way (CL3way), for example.
All Modules must be of the same Module type, 
such as a Classic 3-Way (CL3way), for example.
2.  From the GROUPS menu, tap GANG.
3.  Tap the Module on the scroll bar to select which Module’s settings will be transferred to all other 
Modules in the Group.
4.  Tap GANG XOVER/AUX (Contour Modules) or GANG HPF/LPF (Mesa EQ Modules).
5.  Tap YES to the warning message.
Only the XOVER/AUX/HPF/LPF and associated 
OUTPUT EQ data is ganged. LEVELS data and 
INPUT EQ (PEQ/BLEQ/GEQ) cannot be ganged. Use 
Group EQ/LEVELS to control multiple Modules.
To synchronize all data across multiple Modules, 
you can use the powerful SUPER MODULE 
feature. Refer to section 8.8 for details.
10.8  Add Page 
The ADD PAGE function is always available from the GROUPS menu and creates additional pages that help 
manage large systems with many Module and Group icons.