Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
 - 2. Software Installation
 - 3. Network & Firewall Overview
 - 4. Lake Controller Tutorial
 - 5. Home Menu Reference
 - 6. EQ/Levels Menu Reference
 - 7. System Store Recall Menu Reference
 - 8. Modules Menu Reference
 - 10. Groups Menu Reference
 - 11. Solo/Mute Menu Reference
 - 12. Icon Control Menu Reference
 - 13. User Preferences Menu Reference
 - 14. Pages Menu Reference
 - 15. Network Menu Reference
 - 16. Communication and Synchronization
 - 17. Faults and Warnings
 - 18. Analyzer Plug-in
 - 19. Designer Mode Menu Reference
 - 20. Lake-enabled Amplifier Reference
 - 21. LM Series Reference and Operation
 - 22. MY8-LAKE Reference and Operation
 - 23. Keyboard Shortcuts
 - 24. External Control Interfaces
 - 25. Command Line Options
 - 26. Firmware Update
 - 27. Preset Manager
 - 28. IP Address Reference
 - 29. Corporate Information
 
106  
Lake Controller Operation Manual Rev 1.5.9
EQ/Levels Menu Reference
EQ added to an Aux tab affects only the associated output. Module and Group input EQ (PEQ/BLEQ/GEQ) 
still affects all outputs of the Module.
6.5.4  High-pass and Low-pass Filters
The high-pass and low-pass lter controls are located under the AUX OUTPUT FUNCTIONS submenu.
1.  With the AUX-1 tab selected, tap AUX OUTPUT FUNCTIONS
2.  Tap HPF ENABLE then tap LPF ENABLE
Figure 6-22: Aux Output with HPF and LPF Enabled
To adjust the slope of these lters:
1.  Tap FILTER SELECT 
A scroll bar appears displaying available HPF/LPF types.
2.  Drag the scroll bar or use the << and >> buttons to view available lters.
3.  Select the 24dB LINKWITZ/RILEY lter from the scroll bar.
4.  Tap FILTER SET to activate this lter, then YES to the warning message.