Current Draw & Thermal Dissipation
D SERIES 200:4
WWW.LABGRUPPEN.COM
The following tables contain information on measured current consumption as well as calculated heat dissipation during what we see as
the most extreme sustained normal operation (1/8 rated power), all channels driven.
D SERIES 200:4
Level Load
Rated power
per channel
Line Current
Power
Factor
Measured Power (W) Thermal Dissipation
(A) (%) In Out Dissipated BTU/hr kCal/hr
Mains Voltage 100 VAC, 30 A
Sleep (Tesira) 0.2 34 8 0 8 27 7
Standby (Lake) 0.3 52 17 0 17 58 15
Standby (Tesira) 0.4 48 19 0 19 63 16
Power on, Idling 2.4 97 235 0 235 802 202
Pink Pseudo
Noise
16 Ω / Ch. 115 0 12.1 99 119 2 588 604 2061 520
8 Ω / Ch. 2300 22.3 99 2198 1174 1024 3493 881
4 Ω / Ch. 4400 29.2 99 2853 1478 1375 4691 118 3
2.67 Ω / Ch. 5000 29.2 99 2862 1399 1463 4991 1259
2 Ω / Ch. 4400 29.1 99 2826 1355 1472 5022 1266
LoadPilot
Sine 20 kHz
8 Ω / Ch. 2.5 97 236 0 236 807 203
Mains Voltage 120 VAC, 30 A
Sleep (Tesira) 0.2 30 8 0 8 28 7
Standby (Lake) 0.3 48 17 0 17 58 15
Standby (Tesira) 0.4 43 19 0 19 65 16
Power on, Idling 2.0 97 227 0 227 775 195
Pink Pseudo
Noise
16 Ω / Ch. 115 0 12.0 99 118 0 588 593 2023 510
8 Ω / Ch. 2300 18.4 99 2144 1174 970 3310 835
4 Ω / Ch. 4400 30.0 99 3457 1896 1561 5326 1343
2.67 Ω / Ch. 5000 29.5 99 3439 1752 1687 5756 1451
2 Ω / Ch. 4400 29.9 99 3495 1665 1830 6245 1575
LoadPilot
Sine 20 kHz
8 Ω / Ch. 2.0 97 232 0 232 790 199
Mains Voltage 208 VAC, 17.3 A
Sleep (Tesira) 0.3 30 9 0 9 30 8
Standby (Lake) 0.3 27 18 0 18 60 15
Standby (Tesira) 0.4 25 19 0 19 65 16
Power on, Idling 1.2 92 222 0 222 757 191
Pink Pseudo
Noise
16 Ω / Ch. 115 0 5.7 99 1151 588 564 1923 485
8 Ω / Ch. 2300 10.2 99 2055 1174 881 3005 758
4 Ω / Ch. 4400 16.2 99 3286 1948 1338 4565 1151
2.67 Ω / Ch. 5000 15.6 99 3171 1752 1419 4843 1221
2 Ω / Ch. 4400 16.0 99 3253 1665 1589 5420 1367
LoadPilot
Sine 20 kHz
8 Ω / Ch. 1.2 92 229 0 229 780 197
Current Draw and Thermal Dissipation
D SERIES: High-Power Installation Platform