Current Draw & Thermal Dissipation
D SERIES 120:4
Item no. CDTD-DSERIES1204 - 09.09.2015
WWW.LABGRUPPEN.COM
D SERIES 120:4
Level Load
Rated power
per channel
Line Current
Power
Factor
Measured Power (W) Thermal Dissipation
(A) (%) In Out Dissipated BTU/hr kCal/hr
Mains Voltage 230 VAC, 16 A
Sleep (Tesira) 0.3 13 12 0 12 40 10
Standby (Lake) 0.3 18 13 0 13 43 11
Standby (Tesira) 0.3 20 14 0 14 49 12
Power on, Idling 1.0 90 205 0 205 698 176
Pink Pseudo
Noise
16 Ω / Ch. 950 4.7 99 1003 475 529 1803 455
8 Ω / Ch. 1900 7.7 99 1734 949 784 2676 675
4 Ω / Ch. 3000 11.4 99 2562 1501 1061 3620 913
2.67 Ω / Ch. 3000 12.8 99 2873 1499 1374 4688 1182
2 Ω / Ch. 3000 13.1 99 2993 1500 1493 5095 1285
LoadPilot
Sine 20 kHz
8 Ω / Ch. 1.0 90 214 0 214 730 184
Current Draw and Thermal Dissipation
D SERIES: High-Power Installation Platform