7.1. Unpacking
Carefully open the shipping carton and check for any damage to the device or the supplied accessories. Every
Lab.gruppen product is tested and inspected before leaving the factory and should arrive in perfect condition. If
any damage is discovered, please notify the shipping company immediately. Only the consignee may initiate a
claim with the carrier or their insurers for damage incurred during shipping. Save the carton and packing materials
for the carrier’s inspection.
7.1.1. Included in the box
In addition to the D Series device, the shipping carton includes the following items:
• D Series Lake Quick Start Guide (this document)
• AC mains lead (power cable) with Neutrik powerCON connector (D 200, D 120 and D 80) or locking IEC
connector (D 40, D 20 and D 10) and AC socket plug according to ordering selection
• Rear brackets for additional rear rack support (pair) along with associated mounting hardware
• Connector kit including all needed connectors
• Front grille and dust fi lter assembly
NOTE: Depending on the model, the connector kit might include more connectors than applicable for
the product you have. Select those connectors required for your unit and application.
Please keep the original carton and associated packaging to facilitate shipping of the device should the need arise.
7.2. Mounting
D Series is made for mounting in 19 inch racks. Four screw holes are available for attachment of the amplifi er to
the racks front rack rail. This device has no top or bottom vents; therefore, units may be stacked directly on top of
one another. Suffi cient space should be available at the rear to accommodate connectors and cables. In addition,
allowance must be made for cable or loom bends within a rack.
7.2.1. Rear Mounting
Two rear support brackets, along with associated mounting hardware, are included with the D Series device. It is
strongly recommended that these are used wherever possible. Fit the brackets to the vertical rails at the rear of the
rack. The following diagrams show the fi tting options for fi xed and removable installation. The support brackets are
reversible and may be fi tted to point either to the front or rear of the rack; the proper orientation depends on the
rack depth and position of the rear rack rails.
Rear support bracket with mounting hardware
Rear support bracket mounted for fi xed Rear support bracket mounted for removable
installation and bracket pointing forward installation and bracket pointing towards back
7.2.2. Mounting front grille
The front grille is shipped on top of the amplifi er inside the box to protect it during shipping. The front grille adheres
to the amplifi er with magnets. Hold the front grille with your fi ngers in each of the side cutouts and slide it gently into
place straight from the front.
NOTE: Always ensure the dust fi lters behind the detachable front panel are clean to allow maximum
possible airfl ow. The exterior front panel is held in place by powerful magnets but is easy to detach by
using your fi ngers in the openings at the each side. To clean the foam fi lter, detach it from the exterior
front and gently use a vacuum cleaner or gently shake it. Remount with the opposite procedure. Never
operate the amplifi er without the dust fi lter installed.