11.6. LoadPilot Load Monitoring 
11.6.1. Introduction 
LoadPilot is a feature in D Series ampliers that can continually monitor the integrity of loudspeakers and cables 
connected to the outputs to ensure that they are functioning properly and free from major anomalies or faults. 
By implementing LoadPilot, systems incorporating D Series ampliers can be certied in compliance with voice 
evacuation standards such as EN54–16 and NFPA72.
LoadPilot functions by automatically superimposing low–level pilot tones on the input signal (if any present) to the 
amplier. One tone is below the range of human hearing (approximately 10–20 Hz) and the other above (24 kHz), 
so the activity of LoadPilot is inaudible regardless of whether the system is currently reproducing program content. 
High–resolution current sensing on the outputs can calculate the impedance of the load at the frequency of the 
tones. Hence a stable measurement of the impedance of the load can be obtained and potential anomalies or 
faults can be detected that would indicate impaired loudspeaker function or total inoperability due to failure of the 
loudspeaker or faults in connected wiring. The superimposition of pilot tones and analysis is interleaved across the 
amplier’s output channels with a maximum total cycle time of around 20 seconds.
LoadPilot is implemented and congured in the CAFÉ software. Monitoring status and fault indication are displayed 
on the front panel and both in CAFÉ and Lake Controller.
LoadPilot may be congured with the automatic calibration or through a manual advanced mode, depending on 
monitoring requirements and characteristics of the connected loudspeaker loads.
11.6.2. Automatic calibration 
11.6.2.1. Functional description 
Automatic calibration is suitable for the following applications and requirements for error detection:
•  If one or two low–impedance loudspeakers are connected; if two in parallel is default, it will warn if one is  
  missing.
•  If there are one or two “spurs” with 70V loudspeakers connected; if two in parallel is default, it will warn if one 
  is missing.
•  If there is a short circuit in the load.
•  If there is an open circuit (all loudspeakers missing).
•  For passive 2– and 3–way loudspeakers, if one or two LF drivers are connected and working; if two in parallel 
  is default, it will warn if one is missing.
•  For some passive 2–way designs, if one HF driver is disconnected. (However, with some loudspeakers the 
  HF impedance is dominated by a passive component i.e. crossover lter and the anomaly will not be detected.)
NOTE: LoadPilot is enabled only when the amplier is On. It does not function while the amplier is in 
Standby.
11. Operation and performance 
D SERIES Lake Operation Manual  rev 3.0.3
31    
11.6.3. Manual configuration 
11.6.3.1. Functional description 
Manual conguration can be used in special cases where proper functioning requires setting of custom 
measurement frequencies, custom measurement levels, custom warning thresholds, or combinations of the three. 
Manual conguration addresses the following issues:
Speakers with non stable impedance – For the LoadPilot feature to function the load itself needs to have a 
stable impedance at the frequency of the tone. Resonances in the speaker or other non linear phenomenons can 
make the impedance at a certain frequency unstable. Stability needs to be veried by examining the impedance 
response to make sure it is relatively at at the tone frequencies and by verifying LoadPilot readings when playing 
signal through the speaker at the most extreme expected level. The frequency of the pilot tones can be changed 
within certain ranges and a tone can be disabled. If a frequency where the speaker is stable can not be found one 
tone can be disabled and LoadPilot relies solely on the remaining tone.
High noise levels – To obtain accurate impedance measurements, it is necessary to drive a current sufciently 
above the noise oor. However, it is important to keep the level low in order to prevent audible artifacts from cone 
travel. At very high impedances, the drive current may be insufcient. In the automatic mode, level is set around 60 
mV which produces usable results for impedance up to 660 ohms.
Inductance in loudspeaker cables – Loudspeaker cable inductance at higher frequencies is very high relative to 
passive resistance, and the inductance increases linearly with length. Consequently, monitoring at the 24 kHz pilot 
tone frequency can be problematic with very long cables. The automatic mode will estimate cable impedance for 
24 kHz and allow it to be used as long as it is less than 33% of total impedance presented by the load and as long 
as the total impedance is below about 440 ohms.
DC blocking capacitors in loudspeakers – Some loudspeakers incorporate a capacitor designed to block 
damaging voltages at very low frequencies. This may inhibit accurate measurements when using the 10 Hz pilot 
tone. In automatic mode, LoadPilot will disable the 10 Hz tone if total impedance is above about 440 ohms.
Constant voltage loudspeakers – Loudspeakers driven via transformers in 70V/100V solutions are more likely 
to exhibit wide variations in measured impedance as music and/or pilot tones are reproduced by the system. Also, 
most constant voltage systems operate more than two loudspeakers in parallel. Therefore, in addition to manual 
conguration of LoadPilot, additional step may be required. These include:
•  Insertion of a series capacitor in each loudspeaker to block the 10 Hz LF tone – This will defeat measuring the  
  loudspeakers with the LF tone, but will allow the LF tone to propagate through the entire cable run.
•  Insertion of EOL (end–of–line) resistors – This enables LoadPilot to detect cable faults in a spur of the system.
•  Insertion of EOL (end–of–line) inductor – This is not mandatory, but it will avoid the loss of level at mid and high  
  frequencies due to the EOL resistor.
NOTE: Manual conguration of LoadPilot is implemented in CAFÉ versions 1.1.0. and later. For detailed 
information on manual conguration of LoadPilot, please refer to the integrated guide in the software 
program and to the CAFÉ Coach videos posted on the Lab.gruppen web site and on the Lab.gruppen 
channel on YouTube.