Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Lake Controller Tutorial
39 
Figure 4-23: LM 26 Output Conguration
The Output Conguration window provides the ability to route any physical input or Module output to any 
available analog or digital output on the device. The arrows below the source and destination labels allow 
selection and mapping of all available I/O. 
LM Series devices provide the ability to route any of the eight the Input Router Outputs directly to any 
output. This allows fail-over input switching to be congured for pass-thru / format conversion purposes. For 
instance, an input router can be congured for fail-over to Analog if AES input fails, and the whichever audio 
is used can be passed through to Dante (or any other output type). For further information, please refer to 
section 21.1. 
5.  Tap the blue EXIT/RETURN button in the bottom right to return to the I/O CONFIG page.
The left side of the I/O CONFIG summary screen provides both clock and INPUT CONFIGURATION func-
tions along with other Frame specic functionality. Status information is provided, and zoom icons open 
pop-up windows for access to conguration parameters.
Lake devices have sophisticated digital clocking systems, allowing selection between internal and external 
clock sources at all standard audio sample rates. By default, all Lake devices (except the MY8-LAKE) use 