Global Events and Control
23.2.5 Global Dual Redundancy Control
Two buttons, ON and OFF, control the Dual Redundancy network status of all devices that are online and
present in the current system conguration (not applicable to MY8-LAKE). A conrmation is required prior to
changing this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.
Status indicators summarize the number of online devices in the current system conguration that have this
status set to ON or OFF.
The power must be cycled on the device for this
parameter change to complete. (i.e. Disconnect or
turn off mains power then reconnect or turn on
mains power).
Please refer to section 8.2.10.5 for further information regarding Dual Redundancy.
23.2.6 Global Dante Enabled Control
Two buttons, ON and OFF, control the Dante Enabled status of all devices that are online and present in the
current system conguration (not applicable for MY8-LAKE). A conrmation is required prior to changing this
status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status. Status indicators summarize the number of online devices in the current system
conguration that have this status set to ON or OFF.
Two additional buttons, 48 kHz and 96 kHz control the Dante sample rate for all Dante-enabled devices in
the current system conguration.
One additional button, “Copy Frame Label”, will copy all unique Frame Labels in the system and have
these as Dante Device Name for all supported devices. This feature is also available per device in the Dante
Conguration menu.
If a Frame Label is used by 2 or more devices, that Frame Label will not be used at all, and if a Dante Device
Name already is used by another device not included in the system but on the Dante Network, this will also
be skipped. After the operation, a Result report will be displayed.
23.2.7 Global Dante Transmit Enabled Control
Two buttons, ON and OFF, control the Dante Transmit Enabled status of all devices that are online and
present in the current system conguration (not applicable for MY8-LAKE). A conrmation is required prior
to changing this status across all devices.
Both buttons will be blue if a combination of status are present, or one button will be orange if all devices
have the same status.