Global Events and Control
291
If the Global Power Control default sequence time
is too quick, causing issues for the power distribu-
tion, this can be changed from the iC.ini le located
in the Cong folder of Documents. The setting is
GLOBAL_POWER_DELAY and it is specied in ms.
23.2.2 Global Power Channel Mute Control
The Global Mute Control allows global control of all:
▸ Module Input Mutes
▸ Module Output Mutes
▸ Power Channels (Lake-enabled ampliers only).
ALL MUTED and ALL UNMUTED indicate and control the specic mute. A conrmation is required prior to
changing this status across all frames.
Both buttons will be blue if a combination of status are present for the specic mute, or one button will be
orange if all devices have the same status.
Status indicators to the right of the buttons show the total number in the current system conguration that
are MUTED, UNMUTED.
23.2.3 Global Temperature
The current ambient temperature (the temperature of the air surrounding the cabinets) may be entered on
this tab. Tapping on the blue button in the AMBIENT TEMPERATURE box opens a numeric keypad for the
purpose.
The temperature value is transferred to the LOADSmart Table on the MODULE LOADSmart Tab and used
for load verication and monitoring procedures. Buttons allow selection of temperature display in degrees
CELSIUS or FAHRENHEIT.
23.2.4 Global LoadSmart
The GLOBAL LOAD CONTROL VERIFY button initiates the system-wide load verication of all Frames.