Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Global Events and Control
289 
23.1.3  Filtering Options
The default event log records and displays all events for all Modules and Frames in the system. To reduce 
the number of log entries displayed, apply the lter options on the right of the screen. Regardless of ltering 
options currently selected, all events are recorded, and may be displayed later as required.
23.1.3.1  Severity
Recorded events are divided into three categories: FAULTS, WARNINGS and USER ACTIONS. Events in any 
or all of these categories may be displayed in the log by tapping the three buttons in the SEVERITY box. The 
ALL button restores the default state of all three categories being selected.
23.1.3.2  Source
Using buttons in the SOURCE box, events may also be ltered on the basis of which part of the system 
generated them. Any or all of six event sources may be selected, as follows:
 ▸ Loudspeaker Identication
 ▸ Loudspeaker Temperature
 ▸ Amplier Device
 ▸ Amplier Output
 ▸ Other: Audio distribution
 ▸ Other: Network
The ALL button restores the default state of all six categories being selected.
23.1.3.3  Time
It is possible to display only events which have occurred within a user-dened time interval, using the 
buttons in the TIME box. The options are:
 ▸ SINCE HH:MM – Tapping the HH and MM buttons opens a numeric keypad to allow a ‘Start time’ for 
displayed events to be entered. Tapping the SINCE button activates the option.
 ▸ LAST POWER CYCLE – Tapping this button causes the Event Log to only display events which have 
occurred since the last time the was powered up.