Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Module File Types & Lake LoadLibrary™ 
179 
Figure 9-8: Linear Phase 2-Way + 1-Auxiliary Outputs
9.5.2  Linear Phase 3-Way
The Linear Phase 3-Way (LP3way) has a similar signal path to the Classic 3-Way (CL3way).
Figure 9-9: Linear Phase 3-Way
9.5.3  Linear Phase 2-/3-Way EQ/MaxPeak combinations
The LP2 and LP3way Modules use a signicant amount of processing power to create steep crossovers 
with at phase response. For this reason, the full amount of output-specic EQ lters can only be used if the 
MaxPeak is disabled on the Module, as the MaxPeak Limiter also requires a large amount of processing.
The MaxPeak Limiter process is disabled when the total MaxPeak level (including Group and factory set-
tings) is 25 dBu or greater. The following crossover EQ lters for the LP2 and LP3way are available:
 ▸ MaxPeak Activated:  10 EQ Filters + High-pass Filter
 ▸ MaxPeak Deactivated:  15 EQ Filters + High-pass Filter