Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Modules Menu Reference
159 
8.4.3  Replace Frame
The REPLACE function allows transfer of Module/Super Module/Group data between devices. If a previ-
ously used device is unavailable, or the device that performs a task is required to change, follow these 
steps:
1.  Tap COPY/PASTE/REPLACE from the Modules menu.
2.  Tap a Module from the Frame you wish to replace on the work area.
3.  Tap REPLACE FRAME 
The Module scroll bar displays used and unused Modules.
4.  Tap a Module from an unused Frame then tap COMPLETE REPLACE. 
To locate a particular device, tap the SEL button on the front panel to center the unit on the scroll bar:
 ▸ LM Series | Press the top-left dynamic function button on the front panel
 ▸ PLM Series | Press the second dynamic function button down on the left on the front panel
 ▸ PLM+ Series | Press the top-left dynamic function button on the front panel
 ▸ D Series | Press the SELECT button to the far-right of the front panel
8.4. 3.1  Replace Frame Rules and Compatibility 
 ▸ All Modules of a Frame must be present on the Module scroll bar (i.e. no part of the Frame can be in 
use in the current system conguration)
 ▸ Network IP settings and Dual Redundancy conguration are not transferred during a Frame Replace 
operation; congure this manually on the destination Frame. 
 ▸ PLM 10000Q and PLM 20000Q Frames may be replaced with PLM+ or D Series, and will populate 
Modules A&B only. Modules C&D will remain unaffected. 
 ▸ PLM+ or D Series may be replaced with any product from either of these product lines without any 
loss of data. If a destination model cannot set a value contained in the source model, the appropriate 
minimum or maximum will be set and these discrepancies are indicated via the desired values and 
actual values within brackets [ ]. These products may not be replaced by a legacy PLM product. 
 ▸ PLM 14000 can only be replaced with an online PLM 14000.
 ▸ For LM Series and MY8-LAKE devices, the source and destination Frames must be of the same 
conguration type (i.e. Contour, Mesa, or Contour/Mesa), and can only be replaced with a Frame of the 