Lake Controller Operation Manual Version 1.7.0
Lake Controller Operation Manual Rev 1.7.0
Modules Menu Reference
155 
Input Router Mutes are not available when a device 
is ofine.
8. 2 .12  Interactive Signal Path Block Diagram
The signal path of each Module is shown in Graphical form on the right of the I/O CONFIG page. Each of the 
blocks can be selected to navigate directly to the associated EQ/LEVELS/XOVER/AUX/HPF/LPF screens.
After using the interactive block diagrams to access 
the other screens, the EQ/LEVELS EXIT button 
returns you to the I/O CONFIG page instead of 
HOME.
8. 2 .13  Input Selection (MY8-LAKE in Simplied View Only)
The MY8-LAKE device has a unique simplied view for the Mesa Frame conguration by default. In this 
view the input can be easily toggled between default Host output and AES input. Please refer to “8.2.7.2 
Input Mixer” on page 144 and “22.4 I/O Conguration View Mode Options” on page 285 for further 
information.
8. 2 .14  Frame Cong/Soft Reset
For Lake-enabled ampliers this button reads SOFT RESET and resets the device to its factory default state, 
without removing any presets stored in the device, and without resetting the networking conguration data 
including IP Cong, IP Address, Subnet Mask & Dual Redundancy settings.
For LM Series and MY8-LAKE devices, this button reads FRAME CONFIG and provides a sub-menu 
allowing the device to be congured as:
 ▸ CONTOUR (2-Contour Modules for LM Series; 4-Contour Modules for MY8-LAKE) 
 ▸ MESA EQ (4-Mesa EQ Modules for LM Series; 8-Mesa EQ Modules for MY8-LAKE) 
 ▸ CONTOUR/MESA EQ (2-Contour Modules and 4-Mesa EQ Modules for MY8-LAKE)
For all products, conguring or resetting a device via 
the Lake Controller retains the current IP address 
setting and system/Frame presets.