Lake Controller Operation Manual
Table Of Contents
- 1. Welcome
- 2. Software Installation
- 3. Network & Firewall Overview
- 4. Lake Controller Tutorial
- 5. Home Menu Reference
- 6. EQ/Levels Menu Reference
- 7. System Store Recall Menu Reference
- 8. Modules Menu Reference
- 10. Groups Menu Reference
- 11. Solo/Mute Menu Reference
- 12. Icon Control Menu Reference
- 13. User Preferences Menu Reference
- 14. Pages Menu Reference
- 15. Network Menu Reference
- 16. Communication and Synchronization
- 17. Faults and Warnings
- 18. Analyzer Plug-in
- 19. Designer Mode Menu Reference
- 20. Lake-enabled Amplifier Reference
- 21. LM Series Reference and Operation
- 22. MY8-LAKE Reference and Operation
- 23. Keyboard Shortcuts
- 24. External Control Interfaces
- 25. Command Line Options
- 26. Firmware Update
- 27. Preset Manager
- 28. IP Address Reference
- 29. Corporate Information
Lake Controller Operation Manual Rev 1.5.9
LM Series Reference and Operation
277
21.1.2 Conguring Pass-Thru Input to Output via Input Router
To congure the a pass-thru conguration via an input router:
1. Navigate to HOME > MODULE > IO CONFIG > INPUT CONFIGURATION.
2. Congure the input router with the relevant inputs and priorities as described in section 8.2.2.
To route the signal from the pass-thru input routers to a particular output:
3. Navigate to HOME > MODULE > IO CONFIG > OUTPUT CONFIGURATION.
Please refer to section 8.2.8 for further details.
4. Tap the left arrow under the label ‘Source’.
The source will change to display ‘Input Router Outputs’ similar to that shown in Figure 21-3. This
example has the source from Input Router 7 & 8 directly patched to AES4 (Out 7 & 8).
Figure 21-3: Output Conguration - Input Routers selected as Source
5. Use the ‘Destination’ arrows to select the required output type, then select an available (blue) routing
point to connect the signal from the Input Router to one of more outputs.