Lake Controller Operation Manual

Table Of Contents
136
Lake Controller Operation Manual Rev 1.5.9
Modules Menu Reference
that is grayed-out is operating at a different sample rate compared to the selected device; the device will be
unable to lock to this channel until both the channel and the device are operating at the same sample rate.
Figure 8-14: Dante Receivers on Input Conguration scroll bar
If Audinate ‘Dante ConMon” + ‘Dante Discovery’ service are not
running correctly, the Dante Receive Cong is disabled and a
warning displayed top-right of the Receive tab. Verify via Control
Panel Items \ Administrative \ Tools \ Services; restart if required.
PRODUCT DANTE IN DANTE OUT DUAL REDUNDANCY
Lake LM Series 4 channels 8 channels YES
PLM Series 2 channels
2 channels
(unprocessed audio only)
YES
PLM+ Series 8 channels
8 channels
(unprocessed audio only)
YES
D Series 8 channels
8 channels
(unprocessed audio only)
YES
MY8-LAKE N/A N/A N/A
Table 8-3: Dante Input / Output Channels by Product
8.2.5.3 Transmit Tab
When Dante is enabled, by default the device will receive audio but will not transmit audio.
Transmission is disabled in order to prevent unnecessary network trafc and unused channels on
the INPUT CONFIGURATION screen of all other devices on the network.
To transmit Dante channels from a device:
1. Tap the DANTE DISABLED button on the DEVICE tab
2. Tap the TRANSMIT tab
3. Tap the TRANSMIT OUTPUTS button