User guide

5. Operation and Performance
18
C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3
5.4.7 Output Current Peak Limiter (CPL)















If the CPL LED is steadily illuminated orange while the output
is muted and the -4 dB signal LED is NOT on, then the
amplier output is detecting a short circuit or low impedance
condition. The problem can be solved by checking input and
output cables and examining the state of the loudspeaker
load. If there is no short circuit present, then the condition may be rectied
by lowering the VPL or input levels.

