6.4. Current Draw and Thermal Dissipation Specifications
The following tables contain information on measured current consumption as well as calculated heat dissipation
during normal operation (1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
C 20:8X
Level Load Rated power Line Current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby w. remote Power Off via NomadLink 6 0 6 20 5
Power On, Idling 91 0 91 312 79
Amp Watt
Pink noise
(1/8)
70 V / Ch. 250 x8 4,8 2,5 546 250 296 1011 255
16 Ω / Ch. 250 x8
4,2 2,2 486 250 236 807 203
32 Ω / Bridged 500 x4
100 V / Ch. 500 x4 3,6 1,9 418 250 168 573 144
8 Ω / Ch. 250 x8
3,5 1,8 399 250 149 509 128
16 Ω / Bridged 500 x4
4 Ω / Ch. 250 x8
3,4 1,8 376 250 126 431 109
8 Ω / Bridged 500 x4
2 Ω / Ch. 125 x8
2,3 1,2 259 125 134 459 116
4 Ω / Bridged 250 x4
Pink noise (1/4) 70 V / Ch. 250 x8 7,4 3,9 785 500 285 972 245
16 Ω / Ch. 250 x8
7,3 3,8 782 500 282 961 242
32 Ω / Bridged 500 x4
100 V / Ch. 500 x4 6,7 3,5 774 500 274 937 236
8 Ω / Ch. 250 x8
6,7 3,5 772 500 272 928 234
16 Ω / Bridged 500 x4
4 Ω / Ch. 250 x8
6,5 3,4 743 500 243 830 209
8 Ω / Bridged 500 x4
2 Ω / Ch. 125 x8
3,8 2,0 435 250 185 632 159
4 Ω / Bridged 250 x4
*1) The ampli er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
speci ed here is what is known as the “Active Power” in the ampli er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230 V. 115 V gures are 230 V gures multiplied by two.