Operation Manual
4. Product Overview
14
C SERIES Operation Manual rev 2.0.0
VPL - Voltage Peak Limiter adjustment is provided for 8 individual levels. Select the setting most appropriate for
connected speakers. See Appendix for details.
Mode - Select VPL mode between Hard and Soft. For channels driving sub-woofers and low-end frequencies, it
is recommended to use the Hard setting for optimal operation. For mid- and high-frequency drivers, always select
Soft.
GPI 2 Level Trig - Disables GPI 1; GPI 2 turns amplier on when closed, off when open. (See section 5.5).
GPI (- NomadLink) - Disables the amplier’s connectivity to the NomadLink network.
4.3. NomadLink / Ethernet network setup
The amplier includes, as a standard feature, internal facilities for the NomadLink monitoring and control network.
All features of the NomadLink network are accessible via a PC running LAB GRUPPEN’s proprietary DeviceControl
software. A single rackspace NLB60E NomadLink Bridge & Network Controller, the NLB 60E, accepts the
TCP/IP data stream from the computer and converts it to the NomadLink protocols. Even when no computer is
connected, the NLB 60E can initiate stand-alone power on/off and muting functions, as well as report any fault or
warning condition.
The PC is connected to the NLB 60E using a standard Ethernet interface and a crossed Cat-5 cable (peer-to-peer
setup). If a HUB or switch is in the network, standard “straight” Cat-5 cables must be used. The front and rear
Ethernet connections on the NLB 60E can be used individually, but only one PC at a time running DeviceControl
can access the network.
NOTE: Many newer laptop computers will allow peer-to-peer connection with the NLB 60E using a
standard “straight” Cat-5 cable instead of a crossed cable.
The default xed TCP/IP address of the NLB 60E is 192.168.1.166. The subnet mask is 255.255.255.0. For further
system conguration details, please refer to instructions supplied with the NLB 60E unit.
The NomadLink connections between ampliers use standard “straight” Cat-5/RJ45 equipped cables.
NOTE: US National Differences cl.16.3 requires that NomadLink network cables must be rated VW-1.
The OUT port from the NLB 60E must be connected to the IN port of the rst amplier. The OUT port from the rst
amplier in turn connects to the next amplier’s IN port to form a daisy-chain The OUT port on the last amplier is
connected to the IN port on the NLB 60E to close the loop.