The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (1/4 rated power).
C 16:4
Current Draw and Thermal Dissipation
C Series: Dedicated Installation Amplifiers
TEMP
MUTE
BRIDGE BRIDGE BRIDGE BRIDGE
MUTE
F A U L T F A U L T
TEMP
POWER
PAL
OPTION
CH| A CH| B CH| C CH| D
VHF VHF
CPL CPL
VPL | CLIP VPL | CLIP
-4dB -4dB
-10dB -10dB
SIG | HI-IMP SIG | HI-IMP
C16:4
POWER
REMOTE
C SERIES
LABEL AREA
C 16:4
Level Load Rated power Line Current *2) Watt *1) Thermal Dissipation
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power off via NomadLink 0 0 0 0 0
Powered on, idling. 129 0 129 440 111
Amp (I) Watt
Pink noise (1/8
rated power)
8 Ω / Ch. 400 x 4
8.6 4.3 526 200 326 1112 280
16 Ω / Bridged 800 x 2
4 Ω / Ch. 300 x 4
8.2 4.1 485 150 335 1143 288
8 Ω / Bridged 600 x 2
2 Ω / Ch. n.r.
4 Ω / Bridged n.r.
100V / Ch. 400 x 4
7.6 3.8 463 200 263 897 226
200V / Bridged 800 x 2
Pink noise (1/4
rated power)
*3)
8 Ω / Ch. 400 x 4
16.2 8.1 1046 533 513 1749 441
16 Ω / Bridged 800 x 2
4 Ω / Ch. 300 x 4
15.2 7.6 953 400 553 1887 475
8 Ω / Bridged 600 x 2
2 Ω / Ch. n.r.
4 Ω / Bridged n.r.
100 V / Ch. 400 x 4
14.4 7.2 944 533 411 1401 353
200 V / Bridged 800 x 2
Mains connector, 230 V CE version 16 A, CEE7
Mains connector, 115 V ETL version 15 A / 5-15P
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be
tripped even if operation is in excess of max. ratings.