Operation Manual
3. Installation 
C SERIES Operation Manual rev 2.0.0
9 
3. Installation 
3.1. Unpacking 
Carefully open the shipping carton and check for any noticeable damage. Every LAB GRUPPEN amplier is tested 
and inspected before leaving the factory and should arrive in perfect condition. If any damage is discovered, please 
notify the shipping company immediately. Only the consignee may institute a claim with the carrier for damage 
incurred during shipping. Save the carton and packing materials for the carrier’s inspection. Should you ever need 
to ship the amplier, always use the original packaging materials.
3.2. Mounting 
The amplier is two rack units high (2U) and will t into a standard EIA 19” rack. The depth is 343 mm (13.5”).
The weight is approximately 8.5 kg (18.75 lbs.) depending on model type.
Free airow from front-to-rear of the amplier must be possible. Therefore, no doors or rack-lids should be 
mounted in front of or behind the ampliers.
Ampliers may be stacked directly on top of each other. There is no need for spacing in between units, though this 
might enable more convenient installation of cabling on the rear panel. 
3.3. Cooling 
The amplier uses a forced-air cooling system with air ow from front to rear, maintaining a low operating 
temperature within dened limits. Front-to-rear airow is preferred as cooler air is present at the front in nearly all 
applications. (This allows higher continuous power levels without encountering thermal problems.) Never attempt 
to reverse the airow. The amplier modules require a pressure chamber between the fans and heat sink, and this 
effect functions only in one direction.
Make sure that there is an adequate air supply in front of the amplier, and that the rear of the amplier has 
sufcient space to allow the exhaust to escape. If the amplier is rack-mounted, do not use covers or doors on the 
front or rear of the rack.
Should a heat sink overheat, the temperature sensing circuits will mute the overheating channel. If the power 
supply overheats, another sensing circuit will mute all output channels until the power supply cools to safe 
operating temperature. An early warning before shut down will be indicated on the front panel LEDs, and a warning 
will be sent through the NomadLink network.
Always make sure that the dust-lters behind the detachable front panel are clean to ensure maximum possible 
airow.
NOTE: If the amplier malfunctions due to dirty dust lters, any required repairs are not covered by 
the warranty.