Quick Start Guide
26 C Series Quick Start Guide 27
C 68:4
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power o via NomadLink 0 0 0 0 0
Powered on, idling. 133 0 133 454 114
Amp (I) Watt
Pink noise
(⁄ rated power)
8Ω / Ch. 1200 x 4
16.0 8.0 1123 600 523 1784 450
16Ω / Bridged 2400 x 2
4Ω / Ch. 1700 x 4
22.4 11.2 1578 850 728 2484 626
8Ω / Bridged 3400 x 2
2Ω / Ch. 1200 x 4
21.2 10.6 1378 600 778 2655 669
4Ω / Bridged 2400 x 2
100V / Ch. 1600 x 4
21.0 10.5 1463 800 663 2262 570
200V / Bridged 3200 x 2
Pink noise
(¼ rated power)
*3)
8Ω / Ch. 1200 x 4
32.6 16.3 2429 1600 829 2829 713
16Ω / Bridged 2400 x 2
4Ω / Ch. 1700 x 4
38.8 19.4 2697 1700 997 3402 857
8Ω / Bridged 3400 x 2
4Ω / Ch. 1200 x 4
35.2 17.6 2296 1200 1096 3740 942
8Ω / Bridged 2400 x 2
100V / Ch. 1600 x 4
35.4 17.7 2605 1600 1005 3429 864
200V / Bridged 3200 x 2
Mains connector, 230V CE version 16 A, CEE7
Mains connector, 115V ETL version 20 A / 5-20P
*1) The amplier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specied here is what
is known as the “Active Power” in the amplier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230V. 115V gures are 230V gures multiplied by two.
*3) Figures measured at maximum power before amplier protection and limiter features are engaged. Typically this is between ¼ and ⁄ of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.
C 48:4
Level Load Rated power
Line Current *2) Watt *1) Thermal Dissipation
115 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standby with remote power o via NomadLink 0 0 0 0 0
Powered on, idling. 123 0 123 420 106
Amp (I) Watt
Pink noise
(⁄ rated power)
8Ω / Ch. 1000 x 4
13,8 6,9 945 500 445 1518 383
16Ω / Bridged 2000 x 2
4Ω / Ch. 1200 x 4
17,4 8,7 1171 600 571 1948 491
8Ω / Bridged 2400 x 2
2Ω / Ch. 600 x 4
12,4 6,2 769 300 469 1600 403
4Ω / Bridged 1200 x 2
100V / Ch. 900 x 4
13,2 6,6 840 450 390 1331 335
200V / Bridged 1800 x 2
Pink noise
(¼ rated power)
*3)
8Ω / Ch. 1000 x 4
28,2 14,1 2116 1333 783 2670 673
16Ω / Bridged 2000 x 2
4Ω / Ch. 1200 x 4
30,6 15,3 2168 1200 968 3303 832
8Ω / Bridged 2400 x 2
4Ω / Ch. 600 x 4
21,6 10,8 1368 600 768 2620 660
8Ω / Bridged 1200 x 2
100V / Ch. 900 x 4
26,4 13,2 1827 1200 627 2139 539
200V / Bridged 1800 x 2
Mains connector, 230V CE version 16 A, CEE7
Mains connector, 115V ETL version 20 A / 5-20P
*1) The amplier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specied here is what
is known as the “Active Power” in the amplier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw gures measured at 230V. 115V gures are 230V gures multiplied by two.
*3) Figures measured at maximum power before amplier protection and limiter features are engaged. Typically this is between ¼ and ⁄ of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.