Current Draw & Thermal Dissipation
Current Draw and Thermal Dissipation
C Series: Dedicated Installation Amplifiers
C 16:4
WWW.LABGRUPPEN.COM
Item no. CDTD-C16:4 - 03.12.2015
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
TEMP
MUTE
BRIDGE BRIDGE BRIDGE BRIDGE
MUTE
F A U L T F A U L T
TEMP
POWER
PAL
OPTION
CH| A CH| B CH| C CH| D
VHF VHF
CPL CPL
VPL | CLIP VPL | CLIP
-4dB -4dB
-10dB -10dB
SIG | HI-IMP SIG | HI-IMP
C16:4
POWER
REMOTE
C SERIES
LABEL AREA
C 16:4
Level Load Rated power Line current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standy with remote power off via NomadLink®
0 0 0 0 0
Power on, Idling
129 0 129 440 111
Amp (l) Watt *1)
Pink pseudo
noise (1/8
rated power)
8 Ω / Ch.
400 x 4
8.6 4.3 526 200 326 1112 280
16 Ω / Bridged
800 x 2
4 Ω / Ch.
300 x 4
8.2 4 .1 485 150 335 114 3 288
8 Ω / Bridged
600 x 2
2 Ω / Ch.
N.R. *4)
4 Ω / Bridged
N.R. *4)
100 V / Ch.
400 x 4
7.6 3.8 463 200 263 897 226
200 V / Bridged
800 x 2
Pink pseudo
noise (max
power) *3)
8 Ω / Ch. 400 x 4
16.2 8.1 1046 533 513 174 9 441
16 Ω / Bridged 800 x 2
4 Ω / Ch. 300 x 4
15.2 7.6 953 400 553 1887 475
8 Ω / Bridged 600 x 2
2 Ω / Ch. N.R. *4)
4 Ω / Bridged N.R. *4)
100 V / Ch. 400 x 4
14.4 7. 2 944 533 411 1401 353
200 V / Bridged 800 x 2
Mains connector. 230 V CE version
16 A. CEE7
Mains connector. 115 V ETL version
15 A / 5-15P
*1) The amplifier section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” of the amplifier section providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are converted from 230 V figures.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is
momentarily in excess of max. ratings.
*4) Regarding n.r. (not recommended) notes: The amplifier will be fully operational in bridge-mode into 2 or 4 ohms, but due to physical constraints in the
construction, the max. output power will not be significanty higher than running individual channels and therefore this mode of operation is not recommended.