Technology Brief Understanding Relationships Voltage-Current-Impedance
WWW.LABGRUPPEN.COM
Technology Brief: Designing for Great Performances
Appendix
1: To nd the maximum speaker power use the equation:
DB
SPL
 = dB
SPL
/W/M + 10log(P
NOM
 / 1W) - 20log(d
METERS
 / 1M)
To nd the required nominal speaker power PNOM use the equation: 
P
dB-NOM
 = DB
SPL
 + 20log(d
METERS
 / 1M) - dB
SPL
/W/M.
P
NOM
 = 10^(P
dB-NOM
/10)
2: Ohm’s law is a denition based on observations made by German 
physicist Georg Ohm in the early 1800s. He measured current ow 
(I) through various conductors as different voltages V, were applied. 
Ohm found that the ratio of voltage to current (V/I) was always the 
same for the same material. Today we call that ratio resistance, 
measured in ohms and expressed as R = V / I. With a little algebra we 
can rewrite the equation as V = I R or I = V / R. A second denition 
concerns the power dissipated in a resistance. Power in watts is 
dened as P = V I, the product of voltage times current. We can 
use the Ohm’s law forms of V = I R or I = V / R to substitute into 
the power denition for alternate power expressions P = I2 R and  
P = E2 / R, or rearranging, I = SQRT (P / R) or E = SQRT (P R) 
3: For a sinewave, V
PEAK
 = 1.414 V
RMS
. For music, V
PEAK
 is typically 3 
to 10 times V
RMS
 corresponding to +10 to +20 dB of headroom.
Voltage ratios and Gain ratios are often described in decibels. Most 
often the voltage ratio, dBu, is given by the following denition: 
dBu = 20log(V
RMS
 / 0. 775v).
Gain ratios are usually expressed as: dB = 20log(V
OUT
 / V
IN
)
4: We use I = SQRT (P / R) or  E = SQRT (P R) to calculate RMS 
voltage and current. Peak values are (1.414 x RMS).
5: If you want to limit the power to the speaker or ‘P
MAX
’ use the 
equation:
V
RMS
 = SQRT (P
MAX
  R
LOAD
) to set the amplier output VPL voltage 
protection limiter control or V
LIMIT
 to V
RMS
 (or VPK = 1.414 V
RMS
) to 
protect the speakers.
The output voltage V
RMS
 value corresponds to a dBu value of 
dBu
OUT
=20log(V
RMS
 / 0.775). Set the amplier Gain control to 
produce this level for 10 dBu input as given by GdB= dBu
OUT
 – dBu
IN
. 
Alternately, we can map 0 dBu input to V
NOM
 to exchange V
NOM 
for 
V
RMS
, now using the voltage limiter to control nominal output instead 
of maximum output.
Item no. DPA-CS_v3 - 25.04.16