Current Draw & Thermal Dissipation

Current Draw and Thermal Dissipation
C Series: Dedicated Installation Amplifiers
C 10:8X
WWW.LABGRUPPEN.COM
Item no. CDTD-C10:8X - 03.12.2015
The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
C 10:8X
Level Load Rated power Line current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standy with remote power off via NomadLink®
6 0 6 20 5
Power on, Idling
91 0 91 312 79
Amp (l) Watt *1)
Pink pseudo
noise (1/8)
70 V / Ch.
125 x 8
3,2 1.7 338 125 213 726 183
16 Ω / Ch.
125 x 8
2.8 1.5 291 125 166 566 143
32 Ω / Bridged
250 x 4
100 V / Ch.
250 x 4
2.7 1.4 281 125 156 532 134
8 Ω / Ch.
125 x 8
2.5 1.3 254 125 129 439 111
16 Ω / Bridged
250 x 4
4 Ω / Ch.
125 x 8
2.4 1.3 245 125 120 408 103
8 Ω / Bridged
250 x 4
2 Ω / Ch.
63 x 8
1.6 0.9 167 63 104 354 89
4 Ω / Bridged
126 x 4
Pink pseudo
noise (1/4)
70 V / Ch. 125 x 8 5.6 2.9 625 250 375 1280 322
16 Ω / Ch. 125 x 8
4.5 2.3 507 250 257 877 221
32 Ω / Bridged 250 x 4
100 V / Ch. 250 x 4 4.3 2.2 484 250 234 800 201
8 Ω / Ch. 125 x 8
3.5 1.8 390 250 140 478 120
16 Ω / Bridged 250 x 4
4 Ω / Ch. 125 x 8
3.7 1.9 411 250 161 548 138
8 Ω / Bridged 250 x 4
2 Ω / Ch. 63 x 8
2.4 1.2 257 126 131 447 113
4 Ω / Bridged 126 x 4
Mains connector. 230 V CE version
16 A. CEE7
Mains connector. 115 V ETL version
30 A. Twist Lock
*1) The amplifier section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” of the amplifier section providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are converted from 230 V figures.
ON/OFF
C10:8X
REMOTE
C SERIES
LABEL AREA
TEMP
VHF
CPL
VPL | CLIP
SIG | HI-IMP
TEMP
VHF
CPL
VPL | CLIP
SIG | HI-IMP
CH|A CH|B CH|C CH|D CH|E CH|F CH|G CH|H
MUTE
FAU LT
MUTE
FAU LT
MUTE
FAU LT
MUTE
FAU LT
POWER
BRIDGE BRIDGE BRIDGE BRIDGE
PAL

Summary of content (1 pages)