The following tables contain information on measured current consumption as well as calculated heat dissipation during normal operation
(1/8 rated power); and during extreme heavy duty operation (max power).
TEMP
VHF
CPL
VPL | CLIP
SIG | HI-IMP
TEMP
VHF
CPL
VPL | CLIP
SIG | HI-IMP
CH|A CH|B CH|C CH|D
MUTE
FAU LT
MUTE
FAU LT
POWER
BRIDGE BRIDGE BRIDGE BRIDGE
PAL
ON/OFF
C10:4X
REMOTE
C SERIES
LABEL AREA
C 10:4X
Level Load Rated power Line current *2) Watt *1) Thermal Dissipation
120 VAC 230 VAC In Out Dissipated BTU/hr kCal/hr
Standy with remote power off via NomadLink®
6 0 6 20 5
Power on, Idling
51 0 51 312 79
Amp (l) Watt *1)
Pink pseudo
noise (1/8)
70 V / Ch.
250 x 4
2.7 1.4 274 125 149 509 128
16 Ω / Ch.
250 x 4
2.5 1.3 252 125 127 432 109
32 Ω / Bridged
500 x 2
100 V / Ch.
250 x 4
2.0 1.0 225 125 100 341 86
100 V / Ch.
500 x 2
8 Ω / Ch.
500 x 2 2.1 1.1 217 125 92 314 79
16 Ω / Bridged
4 Ω / Ch.
250 x 4
2.3 1.2 230 125 105 359 90
8 Ω / Bridged
500 x 2
2 Ω / Ch.
125 x 4
13 0.7 136 63 73 249 63
4 Ω / Bridged
250 x 2
Pink pseudo
noise (1/4)
70 V / Ch. 250 x 4 4.9 2.6 526 250 276 942 237
16 Ω / Ch. 250 x 4
4.3 2.2 458 250 208 710 179
32 Ω / Bridged 500 x 2
100 V / Ch. 500 x 2 3.3 1.7 384 250 134 456 115
8 Ω / Ch. 250 x 4
3.5 1.8 364 250 114 388 98
16 Ω / Bridged. 500 x 2
4 Ω / Ch. 250 x 4
3.6 1.9 373 250 123 421 106
8 Ω / Bridged. 500 x 2
2 Ω / Ch. 125 x 4
2.2 1.1 219 125 94 321 81
4 Ω / Bridged. 250 x 2
Mains connector. 230 V CE version
16 A. CEE7
Mains connector. 115 V ETL version
30 A. Twist Lock
*1) The amplifier section’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specified here is what is known as the “Active Power” of the amplifier section providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are converted from 230 V figures.