Install Instructions

Mascot ST Tankless Water Heater
Page 43
5.4 Status Display Mode
SECTION 5. Control Display and Operation
To change any of the above listed Status Parameters,
Press and Hold Button B
to get into the Status Display Mode.
Rotate Dial E until you nd the Parameter that you wish to change. Tap Dial E to enter that Parameter.
Adjust to the setting that you require and then press (tap) Dial E to save and to Exit.
Index Parameter Description
A: Li or A: GA Flow 1 Current ow value(Li: L/m, GA: GPM)
b: Fr Fan rpm Current fan rpm value
C: Lc Lock Mode Lock mode is used(On) or unused(oFF)
d: OP OP Temperature Current Operating Temperature
E: dH DHW temperature Current DHW temperature
F: Eh Exhaust Temperature Current Exhaust temperature
h: In Inlet Temperature Current Inlet Temperature
L:rt Running Time Display Running Time
L:rt
1: PH Power Supply Time Power Supply Time: 100 hour increments
2: rh Burner Operating Time
Burner Operating Time: 1 hour incre-
ments
3: rH Burner Operating Time
Burner Operating Time: 1,000 hour
increments
4: It Ignition Attempts Number
Ignition Attempts Number: 10 times unit
displayed
5: IH Ignition Attempts Number
Ignition Attempts Number: 10,000 times
unit displayed
J: AG AGM Position AGM Parameter calibration