Brochure

220
276
431
58
73
114
LS-SW-65C-5
LS-SW-80C-5
LS-SW-120C-5
22
24
28
1
/4
56
61
72
150
150
159
135
134
142
59
1
/4
59
62
1
/2
53
1
/8
52
7
/8
55
3
/4
152
152
161
14
14
16
60
59
60
265
293
415
120
133
188
11
1
/2
11
1
/2
11
1
/2
5
3
/8
5
3
/8
6
3
/8
121
121
124
29
29
29
47
3
/4
47
3
/4
48
3
/4
Commercial Laars-Stor
C
Height Floor
to T&P Conn.
in. cm.
D
Height Floor
to Water Conn.
in. cm.
B
Height Floor
to Heater Top
in. cm.
A
Jacket
Diameter
in. cm.
Capacity
Liters
U.S.
Gal.
48
61
95
Imp.
Gal.
Model
Number
E
Height Floor to
Exchanger Outlet
in. cm.
F
Height Floor to
Exchanger Inlet
in. cm.
H
Height Floor
to Aquastat
in. cm.
Shipping Weight
Approx.
lbs. kg.
LAARS-STOR
COMMERCIAL ENERGY SAVER
SINGLE-WALL INDIRECT WATER HEATER
Laars-Stor
single wall commercial models incorporate a super-efficient heat exchanger. Made of
1.5" diameter carbon steel tubing and coated with a glass-lining, it has a total heat surface area of
27.2 square feet. The result is an exceptional first hour delivery and vast hot water reserves.
Heat Exchanger—Single wall 1
1
2"
glass coated steel.
Factory Installed Sediment Reduction
System—Cold water inlet sediment
reducing device. Helps prevent
sediment build-up in tank. Increases
first hour delivery of hot water while
minimizing temperature build-up at top
of tank.
Three Protective Anode Rods—
Provides added protection against
corrosion for long trouble-free service.
Glass Lined Tank—Laars Heating
Systems water heater tanks are
protected from the corrosive effects of
hot water by an exclusive ceramic
porcelain-like coating.
Fully Automatic Controls—Immersed
Honeywell aquastat.
Factory Installed Nipples—For longer
water heater life, easier installation.
2" Non-CFC foam insulation—Covers
the sides and top of tank to save
energy by retarding loss of heat.
Supply and Return Connections—The
1" NPT female connections are
located on the front for both the boiler
supply and boiler return.
Stand-by Heat Loss—Less than
1
2°F
per hour.
Brass Drain Valve.
T&P Relief Valve Installed—All models
feature opening on side of tank.
Five Year Limited Warranty on Steel
Tank and Heat Exchanger—Heavy
gauge steel automatically formed,
rolled and welded to assure a
continuous seam for glass lining.
One Year Limited Warranty on Parts.
D
B
F
E
G
C
A
ANODE RODS
(TYPICAL)
POTABLE
CONNECTIONS
(TYPICAL)
Meets or exceeds the insulating
standards established under
ASHRAE Standard 90.1b
(current edition).
General: All units are certified at
300 PSI (2068 kPa) test pressure
and 150 PSI working pressure
(1034 kPa). All potable water
connections are
3
4" (19mm) NPT
on 8" (203mm) centers.
Dimensions and specifications
subject to change without notice
in accordance with our policy of
continuous product improvement.
These certified ratings were obtained with a heat source output
rate and flow rate as specified and a 180°F boiler water supply
temperature. Other results will be obtained under different
conditions.
Model
Number
AHRI Certified Water Heater Ratings
SW-65C-5
SW-80C-5
SW-120C-5
First Hour
Delivery
@ 135°F
(Gal.)
405
415
445
Continuous
Draw Rating
@ 135°F
(Gal./Hr.)
370
370
370
Standby
Heat Loss
Rating
(°F/Hr.)
0.7
0.6
0.4
Minimum
Heat Source
Flow Rate
(Gal./Min.)
14.0
14.0
14.0
Minimum
Output Rate
of Heat Source
(BTU/Hr.)
245,000
245,000
245,000
Based on 200°F boiler water temperature and 50°F
potable water inlet.
Model
Number 140°F 115°F
DOE Water Heater Performance
SW-65C-5
SW-80C-5
SW-120C-5
Maximum First
Hour Rating
(Gal.) @
534
546
583
820
834
871
140°F 115°F
Continuous
Draw Rating
(Gal./Min.) @
8.0
8.0
8.0
12.8
12.8
12.8
Approximate
Boiler Output
Needed for
Rating (BTU/Hr.)
420,000
420,000
420,000
Heat Exchanger Head Loss
GPM
5
0.64
8
1.63
10
2.55
12
3.67
14
5.00
Ft. of Hd. Loss