User guide

INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
36
ArtNo.102-0005 - Gas regulator types
Type 1 Type 2
Replace the rings on the burners. Screw in the hexagon
headed venturi to make tting the burners easier. Do not
tighten yet.
When all the burner bases and venturis have been tted
tighten the venturi nuts.
Valve adjustment
Removing the Control Panel
Pull o all the control knobs.
Open both oven doors and remove the xing screws
underneath the control panel.
On single oven models the cooling guide, below the control
panel, and its 4 xing screws must be removed to gain access
to the control panel xings.
Remove the 3 xing screws at the top of the control panel.
Pull the control panel forward. Taking care not to damage it,
by protecting it with cloth for example, rest it on the open
oven doors.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the
stop (Fig. 7.2).
Reassemble
Replace the control panel and secure with xing screws.
Ret the control panel and cooling guide where tted.
If you have lifted the maintop, carefully lower it onto the
range. The burners are protected against the burner ames
going out by Flame Supervision Devices (FSD’s).
Take care when lowering the maintop to locate the FSD
sensor probes (Fig. 7.3) in their holes in the cooktop and the
burner bases.
Gas Regulator
To access the regulator, rst remove the drawer by following
the To remove the drawer’ instruction.
The regulator may be one of two types (Fig. 7.4).
Natural Gas and
Propane Gas
Cooktop Bypass
Center burner
49
Large burners
38
Right front burner
31
Table 7.2
ArtNo.0102-0011 - Screwing
the control valve bypass screw
Fig. 7.2
Fig. 7.3
Fig. 7.4