User and Installation Guide
39
INSTALLATION 
Check the appliance is electrically safe when you have nished.
4-Wire Conduit Installation
Disconnect the supplied power cord from the terminal block 
and ground post. Keep the terminal block parts; you will need 
them. Remove the strain relief clamp from the power cord 
and remove the power cord and strain relief clamp from the 
mounting bracket (Fig. 13.11).
The range is shipped with reducer plates to give a 1 ⁄’’ 
diameter opening for conduit connection (Fig. 13.11). Find 
the reducer plates (Fig. 13.8) in the conversion kit and t 
them to the mounting bracket.
Fit a squeeze connector (not supplied with the range), to your 
conduit. Insert the conduit through the reducer plates on the 
mounting bracket. Allow enough slack to easily attach the 
wires to the terminal block.
NOTE: Do not install the conduit without a squeeze 
connector.
Fit the wires to the ground post and terminal block (Fig. 
13.12)
NOTE: Make sure the wires are completely inserted into 
the terminals and secure connections are made.
Secure the squeeze connector in place in the bracket by 
tightening the squeeze connector screws.
Ret the electrical connection cover.
Seal the Openings
Seal any openings in the wall behind the range and in the 
oor under the range when hookups are completed.
When all Connections are Completed
MAKE SURE THE FLOW OF COMBUSTION AND 
VENTILATION AIR TO THE RANGE IS UNOBSTRUCTED.
Fig. 13.11 
Fig. 13.12 
Black
Red
White: Neutral
Ground wire