Manual
INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
38
Make sure the inner
rail is forwards
ArtNo.102-0011 - Pressure test point
Pressure Testing
Connect the appliance to the gas supply. Check the appliance 
is gas sound.
The gas pressure can be measured at the pressure test point 
on the appliance side of the pressure regulator (Fig.8-11).
For proper operation, the pressure of LP supplied to the 
regulator must be between 10’’ and 13’’ of water column 
(2.49 – 3.24 kPa).
When checking for proper operation of the regulator, the 
inlet pressure must be at least 1’’ (0.25 kPa) greater than the 
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range 
manifold must remain in the supply line regardless of 
whether natural or LP gas is being used.
To Fit the Storage Drawer
Slide the inner side rails out until fully extended (Fig.8-12). 
Lift the drawer at its sides and locate one of the drawer rails 
(approximately 15 mm) onto an inner side rail (Fig.8-13).
Rotate the drawer to locate the remaining drawer rail onto 
the opposite inner side rail.
Carefully slide the drawer back into the cavity. Some 
resistance will be felt as the drawer rails locate fully onto the 
inner side rails.
Check the appliance is gas sound.
DO NOT use a ame to check for gas leaks.
When using test pressures greater than ½ psig to pressure 
test the gas supply system of the residence, disconnect the 
range and individual shut-o valve from the gas supply 
piping. When using test pressures of ½ psig or less to test 
the gas supply system, simply isolate the range from the gas 
supply system by closing the individual shut-o valve.
Check the operation of all the burners.
Fig.8-11
Fig.8-12
15 mm
Approx.
Fig.8-13