NOTE: Each shielded twisted pair of wires is shielded as well by
metallic shielding and a drain wire connected to this shield-
ing is to be connected in accordance with Table 3–2.
Table 3–2. IEC Cable Pinouts
Cable STP Wire Color IEC Pin TB Pin
1 White / Blue 1 1
Blue / White 11 2
Shield 22 3
Cable
2 White / Orange 2 10
Cable
Group1
Orange / White 12 11
p
Shield 23 12
3 White / Green 3 4
Green / White 13 5
Shield 24 6
Shield Drain NC 16
4 White / Brown 4 7
Brown / White 14 8
Shield 25 9
Cable
5 White / Gray 5 17
Cable
Group 2
Gray / White 15 18
p
Shield 26 19
6 Red / Blue 6 24
Blue / Red 16 25
Shield 27 26
Shield Drain NC 23
7 Red / Orange 8 13
Orange / Red 19 14
Shield 29 15
Cable
8 Red / Green 9 20
Cable
Group 3
Green / Red 20 21
p
Shield 30 22
9 Red / Brown 10 27
Brown / Red 21 28
Shield 31 29
Shield 18 30