Manual
Is
There a
Blockage in the
Pilot Bracket?
21
Problem 1
Pilot Will
Not Light
Is
Thermostat
Set Above Room
Temperature?
Is the
Pilot Orifice
Plugged on the
Inside or
Outside?
Turn Thermostat
Up to Its
Maximum
Setpoint.
Clean the Pilot Orifice by either:
A. Utilizing the Pilot Clean-Out
OR
B. Remove Orifice. Use a Soft Brush
or Compressed Air. If Orifice cannot
be Cleaned, Replace it.
Yes
No
Yes
Yes
Yes
Yes
Is the
Pilot Bracket
Misaligned or
Damaged?
Realign or Replace
the Bracket.
Is the Inner
Combustion Cone
Plugged?
Is There
a Blockage in the
Gas Hose or
Gas Piping?
Remove Blockage with Compressed
Air or Replace the Gas Hose or Pipe
Section. “Bleed” Off any Air from the
Gas Line.
Clean the Inner Cone
According to the Cleaning
Methods as Prescribed in
the Owner's Manual.
Remove the Blockage. Use a
Soft Brush or Compressed Air.
No
No
No
No
Is Proper
Gas Pressure
Supplied to the
Zone Panel or
Heater?
Provide 5 PSIG Gas
Pressure to Zone Panel.
Ensure 20 in. W.C.
Pressure is Delivered to
Heater with Only Pilot
Operating.
Yes
No
Are all Fuel
Supply Valves to
Heater Open?
Open All Fuel
Supply Valves.
Yes
No
Defective Pilot Safety
Control Valve.
Replace the Pilot
Safety Control Valve.
Yes
No