Manual
2244
Combustion Cone Kits
Part Number
21088
No
PPrroobblleemm 55
HHeeaatteerr DDooeess NNoott
RReettuurrnn BBaacckk ttoo
LLooww HHeeaatt..
Does
Main Burner Shut Off
When Thermostatic Head is
Set Below Room
Temperature?
Remove Thermostatic Head from Modulating Valve Assembly:
A. If Heater Returns to Low Fire When you Push Down on Plunger Pin of Valve,
Replace Thermostatic Head/Sensor Assembly.
B. If Heater Still Does Not Cycle to Low Fire, the Modulating Valve is Sticking and
Should be Replaced.
HHeeaatteerr
BBaacckkffllaasshheess
GGaass TThhrroouugghh
AAiirr IInnlleett..
PPrroobblleemm 44
Is Inner
Cone Seam
Fractured or is Tip
Damaged or
Missing?
Replace Combustion Cone.
Yes
No
Are
Injector
Body, Orifices,Filter,
Venturi Tube, or Inner
Cone Partially Plugged
with Dirt?
Clean these
Components.
No
Is Proper
Gas Pressure
Being Supplied to
the Heater?
Check for Proper
Gas Pressure.
Proper Pressure at
High Heat Should
Read 5 PSIG.
Yes
No
Yes
Are Burner
Assembly
Nuts Loose?
Yes
Tighten the Nuts
Is the Burner
Plate or Burner
Gasket
Cracked?
Yes
Replace the Burner
Plate.or Gasket
No
No
Is Inner Cone
Weld Seam
Aligned to
Burner Plate
Notch?
No
Position the Inner Cone
Weld Seam in Burner
Plate Notch.